Back to top
22 KV Gang Operated Air Break Switch
22 KV Gang Operated Air Break Switch
22 KV Gang Operated Air Break Switch
22 KV Gang Operated Air Break Switch
22 KV Gang Operated Air Break Switch
22 KV Gang Operated Air Break Switch

22 KV Gang Operated Air Break Switch

Price 17000.00 INR/ Set

MOQ : 1 Set

22 KV Gang Operated Air Break Switch Specification

  • Product Type
  • Electrical Overhead Line
  • Material
  • Porcelain Insulator, Brass Contacts, G.I. Channel, Copper Tape, Bolts & Nuts
  • Welding Standard
  • As per IS Specifications
  • Application
  • Pole Line Fittings and Substation Fittings
  • Galvanization Standard
  • IS SPECIFICATION
  • Out Coating
  • Galvanized Channel
  • Standard
  • IS Specifications
  • Shape
  • N.A.
  • Surface Treatment
  • Non Ferrous Parts are Silver Plated
  • Voltage
  • 22 KV Volt (v)
  • Design
  • As per Drawing
  • Thickness
  • As specified in IS Specifications Millimeter (mm)
  • Color
  • Silver
  • Warranty
  • 12 Months
 

22 KV Gang Operated Air Break Switch Trade Information

  • Minimum Order Quantity
  • 1 Set
  • FOB Port
  • HOWRAH
  • Payment Terms
  • Cash Advance (CA), Cheque, Telegraphic Transfer (T/T)
  • Supply Ability
  • 100 Sets Per Month
  • Delivery Time
  • 30-45 Days
  • Sample Available
  • No
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • Air Break Switch in wooden box, Small spare parts in gunny bags and Operating pipe and Tandem Square bar in loose bundles.
  • Main Domestic Market
  • All India
  • Certifications
  • Routines Test Report
 

About 22 KV Gang Operated Air Break Switch

We are an unparalleled name, engaged in offering a premium quality range of G.O.A.B Switches that is widely used in Electrical Overhead Transmission Lines for the action of ON or OFF the charged lines as and when required on break down or maintenance of the lines as and when required. These products are manufacturer as per the IS Specifications by our skilled professionals using the finest quality raw material to ensure its durability. The switches goes through various qualitytests under the strict supervision of our expert quality controllers. This GOAB Switch can be availed from us at market leading price.

Features:

  • Easy to install
  • Sturdy design
  • Dimensionally accurate
  • Rust resistance

ELECTROMECH make Gang Operated Air Break Switch off load disconnecting switch single break tilting type. The switch can be single stack/double stack type.

For 22KV the symmetry of Insulators would be 11KV+11KV double stack or 22KV Post directly.

(We also manufacture double break horizontal [Rotating] type Isolators) with earth blade, Auxillary switch & interlocking arrangements, Insulators, contacts, channel and operating mechanism in all the above variety would be of the following type.

Each pole consists of hot dip galvanized steel channel base, Insulators as per BSS/ISS non ferrous knife and spring loaded contacts arching horns of adequate section to break magnetizing current of the transformer, horizontal G.I. pipe of adequate length for phase separation and operation from ground level with operating handle complete in both ON and OFF position. All ferrous parts are hot dip galvanized and nonferrous parts tinned duly to withstand weather conditions.

Manufactured as per ISS suitable for horizontal-vertical mounting as per ISS -9921 (Part-IV)-1985 reaffirmed 2002.

TECHNICAL SPECIFICATION

Usage/Application

OVERHEAD LINE

Power/Voltage

11 KV TO 33 KV

Voltage Level

High-Voltage

Brand

ELELECTROMECH INSULATORS & SWITCHGEARS

Number Of Insulator

9 OR 18

Current Rating (Amps)

200, 400, 630, 800, 1250 AMPS




Stringent IS Specification Compliance

The switch is meticulously designed and manufactured as per Indian Standards (IS) specifications, ensuring optimal performance, safety, and compatibility for the Indian electrical grid. Each component, from the galvanized channel to the silver-plated non-ferrous parts, adheres to these recognized benchmarks.


Corrosion-Resistant Durability

Every switch comes with a galvanized channel and silver-plated non-ferrous parts, providing robust protection against rust and environmental wear. This guarantees a prolonged operational lifespan, making it ideal for outdoor pole line and substation installations.


Versatile Application

Designed for pole line fittings and substation fittings, this 22 KV air break switch serves as a reliable isolation solution in a wide range of electrical infrastructure projects. Its sturdy construction supports effective operation in demanding electrical environments across India.

FAQs of 22 KV Gang Operated Air Break Switch:


Q: How is the 22 KV Gang Operated Air Break Switch installed?

A: Installation should be carried out on utility poles or substation structures as per the specified drawing and IS Specifications. The switch is typically fitted using galvanized channels, bolts, and nuts provided, and it must be connected to compatible copper tape and aligned with system insulation requirements.

Q: What components are included in the construction of this switch?

A: Key components include a porcelain insulator for voltage resistance, brass contacts for conductivity, a G.I. (galvanized iron) channel for structure, copper tape, and high-quality bolts and nuts. Non-ferrous parts are silver plated as per IS Specifications to enhance durability.

Q: When should this air break switch be used in a power distribution system?

A: This switch is recommended for use in 22 KV pole line and substation applications where reliable isolation and sectionalizing are required for maintenance or safety purposes. It is suitable for new installations and replacement projects.

Q: Where is the 22 KV Gang Operated Air Break Switch most commonly applied?

A: The switch is predominantly installed on overhead pole lines and within substations as part of medium voltage power distribution systems, especially in Indian infrastructure following IS Specifications.

Q: What is the benefit of silver plating the non-ferrous parts of the switch?

A: Silver plating significantly enhances the corrosion resistance of non-ferrous parts, reduces electrical resistance, and ensures better long-term performance even under demanding environmental conditions.

Q: How does the galvanization of the channel increase the products lifespan?

A: Galvanization protects the steel channel from rust and corrosion. This ensures structural integrity over time, making it especially valuable for outdoor installations exposed to the elements.

Q: What warranty and standards apply to this air break switch?

A: The product comes with a 12-month warranty and is designed, welded, and surface-treated in strict accordance with IS Specifications, ensuring dependable quality and compliance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Break Switches Category

11 Kv Rotating Isolator

11 Kv Rotating Isolator

Price 16000-18000 INR / Set

Minimum Order Quantity : 1 Set

Voltage : 11 KV

Warranty : 12 Months

Application : Electrical Distribution Lines

11 KV 2 Post Air Break Switch

11 KV 2 Post Air Break Switch

Price 6400.00 INR / Set

Minimum Order Quantity : 1 Set

Voltage : 11000 Volt (v)

Warranty : 12 Months

Application : Pole Line Fittings and Substation Fittings

11 KV Air Break Switch

11 KV Air Break Switch

Price Range 7000.00 - 9000.00 / Set

Minimum Order Quantity : 1 Set

Voltage : 11 KV Volt (v)

Warranty : 12 Months

Application : Pole Line and Substation Equipment

11kv Air Break Switch With D O Fuse

11kv Air Break Switch With D O Fuse

Price Range 14000.00 - 18000.00 INR / Set

Minimum Order Quantity : 1 Set

Voltage : 400 Ampere (amp)

Warranty : 12 Months

Application : Pole Line Fittings and Substation Fittings