About 30 Kv Polymer Lightning Arrester
30 Kv Polymer Lightning Arrester
30 KV Polymer Lightning Arrester suitable for 33 KV Distribution and Subtstations. Available in Class-I, II and III.
The Specifications are as follows:
- Highest System Voltage: 36 KV
- Nominal System Voltage: 33 KV
- Rated System Voltage: 30 KV
- Nominal Discharge Current: 10KA
- Discharge Class: I, II and III
- Creepage Distance: 900 mm
- Accessories: Mounting Bracket or Base Plate, Terminal Connectors.
Custom-Engineered to Your RequirementsEach 30 kV polymer lightning arrester is designed and manufactured precisely as per your supplied technical drawings, ensuring optimal compatibility with your electrical installations. This customization enables a seamless fit in both pole line and substation applications, promoting swift integration and operational efficiency.
Built to International StandardsBy adhering to IEC specifications, these arresters deliver reliable performance and meet rigorous safety criteria. The use of high-grade polymers and a round profile enhances their durability and resistance to environmental stress, resulting in prolonged service life and reduced maintenance requirements.
FAQs of 30 Kv Polymer Lightning Arrester:
Q: How is the design of the 30 kV polymer lightning arrester customized for each application?
A: The design, including thickness and height, is tailored as per the technical drawings provided by the customer, ensuring the arrester precisely matches specific pole line or substation requirements.
Q: What are the key benefits of using a polymer lightning arrester in electrical installations?
A: Polymer lightning arresters offer superior weather resistance, lightweight construction, and improved durability compared to traditional porcelain arresters, resulting in easier handling and longer service life.
Q: When should the 30 kV polymer lightning arrester be installed in a power distribution system?
A: Installation is recommended during new pole line setups or substation upgrades, especially in regions susceptible to frequent voltage surges caused by lightning or switching events.
Q: Where can these lightning arresters be used?
A: These arresters are suitable for pole line fittings and substation fittings, making them ideal for electrical infrastructure projects across distribution networks in India.
Q: What is the manufacturing process for the polymer lightning arrester?
A: Each arrester is produced using high-grade polymer materials, molded according to IEC standards and the specifications detailed in customer drawings, guaranteeing quality and reliability.
Q: How do I ensure correct usage and maximum benefit from this lightning arrester?
A: Follow installation guidelines based on provided drawings, periodically check for physical damage, and verify that the arrester aligns with IEC standards for optimal protection and performance.